Designed & Made in the USA Since 1983

54-115-336 RS-232 Cable – Fowler/Sylvac Duplex Opto

SKU 54-115-336 Category

RS-232 interface cable for Fowler, Sylvac, and other gages that use the Duplex Opto serial interface. Connects the gage’s Duplex Opto output port to a DB9 host interface for two-way communication — the host can issue a data request to the gage instead of relying on a button press at the instrument. Compatible with WedgeLink AT, WedgeLink SP, MobileCollect RS-232 Remote, and GageWay Pro (Level Converter Cable required for GageWay Pro front channels). When paired with any of the above, measurement data outputs as keystrokes or USB serial — ready for direct input to SPC software or any data collection application.

Duplex or Simplex? These cables are not interchangeable. The Duplex Opto and Simplex Opto ports use the same physical connector but different pin assignments — a simplex cable on a duplex gage will not communicate. If your gage is a Simplex Opto instrument, order the 54-115-333 instead.

OEM Part Number –  54-115-336
Gage Connector –  Duplex Opto
Host Connector – DB9 Female
Length – 6 feet
Compatible Interfaces – WedgeLink ATWedgeLink SPMobileCollect RS-232 RemoteGageWay Pro (Level Converter for front channels)
Cable Type – RS-232 Serial
Data Send Button – No
Compatible Gages – Fowler, Sylvac, and other Duplex Opto-equipped gages

$209.00

Duplex Opto RS-232 Cable — Fowler, Sylvac & Multi-Brand Data Collection

The 54-115-336 RS-232 cable connects the Duplex Opto serial output port of your Fowler, Sylvac, or other compatible gage to a data collection host — eliminating manual transcription of measurement readings and enabling direct output to SPC software, inspection databases, or any application that accepts RS-232 serial data.

The gage-side connector mates with the Duplex Opto data output port on the instrument. The host side terminates in a DB9 female connector, compatible with WedgeLink keyboard wedges, MobileCollect RS-232 Remote wireless transmitters, and GageWay Pro wired interfaces.

Unlike the Simplex Opto interface, which sends data one way from the gage to the host, the Duplex Opto interface is bidirectional. The host can issue a data request command to the gage, so readings can be triggered from the collection point rather than from a button on the instrument — useful for fixtured, automated, or operator-paced inspection stations where reaching the gage is impractical.

Multi-Brand Compatibility

The Duplex Opto interface is used across several gage manufacturers — not exclusively Fowler and Sylvac. If your gage uses the Duplex Opto connection, this cable will work regardless of brand. Common applications include indicators, bore gages, and calipers from:

  • Fowler — Ultra Digit Mark V and other indicators with Duplex Opto output
  • Sylvac — indicators, bore gages, and calipers with Duplex Opto output
  • Other brands using the Duplex Opto serial interface

Not sure if your gage uses the Duplex Opto interface? Use the MobileCollect Selection Tool to look up your specific model from a database of over 3,500 gages, or contact sales@microridge.com.

Configuring RS-232 Output on Your Gage

Before connecting the cable, verify the gage’s RS-232 communication parameters match your receiving interface. Fowler and Sylvac Duplex Opto instruments typically default to 4800 baud, 7 data bits, even parity, 2 stop bits. WedgeLink and GageWay Pro both support auto baud rate detection, which simplifies initial setup. For specific RS-232 settings and the remote command set supported by your instrument, refer to the manufacturer’s documentation or contact your gage manufacturer.

Refer to your WedgeLink or GageWay Pro documentation for host-side comm parameter configuration and for sending gage request commands.

Compatible Interfaces

WedgeLink AT / WedgeLink SP — WedgeLink keyboard wedge technology translates the Duplex Opto RS-232 serial output into keystrokes, sending measurement readings directly into Excel, SPC software, or any application that accepts keyboard input — no software integration required.

MobileCollect RS-232 Remote — For wireless data collection without cable runs between the gage and the collection point, the RS-232 Remote pairs with this cable to transmit measurement readings wirelessly over MobileCollect’s RM2.4 proprietary protocol.

GageWay Pro — Connects to the GageWay Pro via the multifunction serial port or the front gage channels (Level Converter required for front channels).

Other Versions of This Cable

MicroRidge offers the 54-115-336 cable/connector for other systems in the MobileCollect product family:

M3 Connector — Fowler/Sylvac Duplex Opto (MC-M3-54-115-336) — For wireless data collection without a cable run to a host PC. Pairs with the Mini Mobile Module EVO (M3E) transmitter, integrating directly into the MobileCollect wireless network.

Frequently Asked Questions

Q: What is the difference between the Duplex Opto and Simplex Opto cables?

— Simplex Opto is a one-way interface — the gage sends data to the host and cannot receive commands. Duplex Opto is bidirectional, so the host can request a reading from the gage. The two connectors are physically similar but use different pin assignments, so the cables are not interchangeable.

Q: Does this cable work with brands other than Fowler and Sylvac?

— Yes. The Duplex Opto interface is used across multiple gage manufacturers. If your gage uses the Duplex Opto serial output port, this cable is compatible regardless of brand.

Q: What software can I send measurement data to with this cable?

— The cable itself carries only RS-232 serial data between the gage and the host connector — it does not convert that data on its own. Paired with a MicroRidge interface (WedgeLink AT/SP, MobileCollect RS-232 Remote, or GageWay Pro), the reading is converted to keystrokes or USB serial output, so it can be sent to any software application that accepts keyboard input or USB serial data — including SPC programs, Excel, custom inspection databases, and MES systems.

Q: Do I need to configure baud rate settings on my gage?

— The gage’s RS-232 comm parameters must match the receiving interface. Fowler and Sylvac Duplex Opto instruments typically use 4800 baud, 7 data bits, even parity, 2 stop bits. WedgeLink and GageWay Pro both support auto baud rate detection, which simplifies initial setup.

Q: What if I need a wireless solution instead of a wired cable?

— The M3 Connector — Fowler/Sylvac Duplex Opto pairs with the Mini Mobile Module EVO to transmit measurement data wirelessly to any MobileCollect Base receiver.

Product Specifications

54-115-336 Specs
OEM Part Number
54-115-336
Gage Connector
Duplex Opto
Host Connector
DB9 Female
Length
6 feet
Compatible Interfaces
WedgeLink AT, WedgeLink SP, MobileCollect RS-232 Remote, GageWay Pro (Level Converter for front channels)
Cable Type
RS-232 Serial
Data Send Button
No
Compatible Gages
Fowler, Sylvac, and other Duplex Opto-equipped gages

We're exhibiting at IMTS | Sept 14-19 | McCormick Place in Chicago, Illinois