Mitutoyo Digimatic indicators (ID-C, ID-S, ID-U, ID-N, ID-B, ID-F and ID-H) are the workhorse of fixtures, stands and bore gages. Two things set them apart from calipers and micrometers: Mitutoyo changed the ID-C and ID-F connector in 2023, and indicators have no data button, so you decide how each reading is triggered. This page covers both, with the cable for every Mitutoyo indicator in the System Builder.
Find your Mitutoyo indicator in the builderOr describe your application to the System Advisor
Counts come from the MicroRidge Measurement Collection System Builder and update when the gage data does.
Match the cable to the indicator generation
- 905338 (type F, flat straight) fits ID-C indicators made before the NX models, including the 543-390B (ID-C112XB) and 543-400B, plus ID-S and ID-U indicators. The 2 m version is 905409. A right-angle MobileCollect connector (905691 style) is available where a straight plug does not clear the fixture.
- 06AGL011 (type SF) fits the NX generation: ID-C models 543-70X to 543-73X and ID-F models 543-851 to 543-858, with NX in the model name, such as the 543-702 (ID-C0512ENX). These have Mitutoyo’s Digimatic S1 output and a connector that does not mate with the 905338. The 2 m version is 06AGL021.
- 21EAA194 (type G, flat and waterproof) fits the IP66 ID-N and ID-B indicators, 543-57X and 543-58X. The 2 m version is 21EAA190.
- 936937 (type D, flat 10-pin) fits older ID-F and ID-H indicators and similar gages. It looks like the type F plug but does not mate with it.
The connector changes guide shows how to tell an NX indicator from an earlier one. The 06AGL011 support post lists the NX models, and new ID-C/ID-F indicator and SF connector covers firmware for transmitters bought before mid-2023.
| Gage connection | Models | Wireless (MobileCollect) | Wired (GageWay) |
|---|---|---|---|
| 905338 Series 543, 575 | 197 |
| |
| 06AGL011 Series 543 | 78 |
| |
| 936937-EP Series 543 | 22 |
|
|
| 937387 Series 543 | 11 |
| |
| 21EAA194 Series 543 | 8 |
| |
| 937386 Series 543 | 4 |
|
|
| RS-232, DB9 female Series 543 | 4 | Ask MicroRidge | Not offered |
Prices are U.S. list. The builder adds the base receiver or GageWay interface for your computer and checks each model.
Triggering readings without a data button
Pick the trigger that fits the job:
- Read button on the transmitter. The Mini Mobile Module EVO and the Command Mobile Module have their own read buttons.
- Foot or hand switch. Keeps the operator’s hands on the part. It plugs into a Digital Remote or a GageWay Pro channel, or into a full-size MobileCollect base to trigger Command Mobile Modules.
- Software request. TriggerSync lets your software request a reading from a Mini Mobile Module EVO, and the Command Mobile Module takes read commands from the base or your software.
- Continuous or TIR. MobileCollect transmitters can stream readings or report the total indicator reading for runout checks. See wireless TIR.
Stands, fixtures and bore gages
Indicators that stay in a fixture are a good fit for wired collection. The Mitutoyo cable plugs straight into a GageWay Pro, which reads several indicators at one station. Our check fixture data collection guide covers multi-indicator fixtures. The Digital Remote takes the same Mitutoyo cable and adds wireless delivery for a stand that is away from the computer.
Mitutoyo indicator series
| Series | Gage types | Models | Connection |
|---|---|---|---|
| 543 | Indicator, GO/NG Indicator, Digital Indicator | 333 | 905338, 06AGL011, 936937-EP; 14 without data output |
| 575 | Indicator | 5 | 905338 |
| 513 | Quick Set Test Indicator | 1 | 1 without data output |
| 700 | Quick-Mini Comparator | 1 | 1 without data output |
Questions
Indicators with NX in the model name use the 06AGL011 cable (type SF) or the MobileCollect connector for it. Earlier ID-C indicators use the 905338. The two connectors do not mate. Yes. NX indicators have Mitutoyo’s Digimatic S1 output, and GageSync on an EVO base reads the serial number, model and calibration dates. See GageSync and TriggerSync. On indicators with the type F port, yes. The caliper cable has a data button, which you can use to send readings from the indicator. The 905338 has no button. A GageWay Pro8 takes eight gages, and GageWay Pros can be chained to 72 inputs. A MobileCollect base accepts as many wireless transmitters as you need.My new ID-C indicator does not fit my old cable. What do I need?
Can a MobileCollect system read the serial number from an NX indicator?
Will a 959149 caliper cable work on an indicator?
How many indicators can one computer collect from?
Every Mitutoyo indicator in the builder
Select a model to open it in the System Builder with the transmitter, cable and base.
543 series: 543-110, 543-110B, 543-111, 543-113, 543-117B, 543-122B, 543-135B, 543-142, 543-177, 543-177B, 543-180B, 543-250, 543-250B, 543-251, 543-251B, 543-252, 543-252B, 543-253, 543-253B, 543-254, 543-254B, 543-255, 543-255B, 543-256, 543-256B, 543-257, 543-257B, 543-258, 543-258B, 543-259, 543-259B, 543-260, 543-261, 543-262, 543-263, 543-264B, 543-265B, 543-266B, 543-267B, 543-270, 543-270B, 543-271, 543-271B, 543-272, 543-272B, 543-274, 543-274B, 543-275, 543-275B, 543-276, 543-276B, 543-277, 543-277B, 543-278, 543-278B, 543-279, 543-279B, 543-285B, 543-286B, 543-287B, 543-288B, 543-290, 543-290B, 543-291, 543-291B, 543-292, 543-292B, 543-300, 543-300B, 543-301, 543-301B, 543-302, 543-302B, 543-340B, 543-341B, 543-342B, 543-356, 543-383, 543-383B, 543-386, 543-390, 543-390B, 543-391, 543-391B, 543-392, 543-392B, 543-392BS, 543-394, 543-394B, 543-395, 543-395B, 543-396, 543-396B, 543-397B, 543-400, 543-400B, 543-401, 543-401B, 543-402, 543-402B, 543-404, 543-404B, 543-405, 543-405B, 543-406, 543-406B, 543-450B, 543-451B, 543-452B, 543-453B, 543-454B, 543-455B, 543-456B, 543-460B, 543-461B, 543-462, 543-463B, 543-464B, 543-465B, 543-466B, 543-470B, 543-471B, 543-472B, 543-474B, 543-475B, 543-476B, 543-480B, 543-481B, 543-482B, 543-485B, 543-486B, 543-487B, 543-490B, 543-491B, 543-492B, 543-494B, 543-495B, 543-496B, 543-500, 543-500B, 543-501, 543-501B, 543-502, 543-502B, 543-505, 543-505B, 543-506, 543-506B, 543-507, 543-507B, 543-511, 543-513, 543-515, 543-521, 543-523, 543-525, 543-531, 543-533, 543-535, 543-541, 543-543, 543-545, 543-551, 543-552, 543-553, 543-554, 543-557, 543-558, 543-561, 543-561A, 543-562, 543-562A, 543-563, 543-563A, 543-564, 543-564A, 543-570, 543-571, 543-575, 543-576, 543-580, 543-581, 543-585, 543-586, 543-590B, 543-591B, 543-592B, 543-595B, 543-596B, 543-597B, 543-611, 543-611B, 543-612, 543-612B, 543-617, 543-631, 543-631B, 543-681, 543-681B, 543-682, 543-682B, 543-683, 543-683B, 543-690, 543-690B, 543-691, 543-691B, 543-692, 543-692B, 543-693, 543-693B, 543-694, 543-694B, 543-695, 543-695B, 543-696, 543-696B, 543-700, 543-700-02, 543-700B, 543-700B-02, 543-701, 543-701-02, 543-701B, 543-701B-02, 543-702, 543-702-02, 543-702B, 543-702B-02, 543-705, 543-705-02, 543-705B, 543-705B-02, 543-706, 543-706-02, 543-706B, 543-706B-02, 543-707, 543-707-02, 543-707B, 543-707B-02, 543-710, 543-710-02, 543-710B, 543-710B-02, 543-711, 543-711-02, 543-711B, 543-711B-02, 543-712, 543-712-02, 543-712B, 543-712B-02, 543-715, 543-715-02, 543-715B, 543-715B-02, 543-716, 543-716-02, 543-716B, 543-716B-02, 543-717, 543-717-02, 543-717B, 543-717B-02, 543-720B, 543-720B-02, 543-721B, 543-721B-02, 543-722B, 543-722B-02, 543-725B, 543-725B-02, 543-726B, 543-726B-02, 543-727B, 543-727B-02, 543-730B, 543-730B-02, 543-731B, 543-731B-02, 543-732B, 543-732B-02, 543-735B, 543-735B-02, 543-736B, 543-736B-02, 543-737B, 543-737B-02, 543-781, 543-781-10, 543-781B, 543-781B-10, 543-782, 543-782B, 543-783, 543-783B, 543-790, 543-790-10, 543-790B, 543-790B-10, 543-791, 543-791B, 543-792, 543-792B, 543-793, 543-793B, 543-794, 543-794B, 543-795, 543-795B, 543-796, 543-796B, 543-851*, 543-852*, 543-853*, 543-854*, 543-857*, 543-858*
575 series: 575-113, 575-121, 575-122, 575-123, 575-213
Indicators without data output: 513-402, 543-280, 543-280B, 543-281, 543-281B, 543-282, 543-282B, 543-283, 543-283B, 543-350, 543-350B, 543-351, 543-351B, 543-352, 543-352B, 700-XXX. These models have no data output, so no cable or transmitter can read them.