Ohaus balances, bench scales and indicators send weights over RS-232, either from a built-in port or through an optional interface kit. MicroRidge reads that output wirelessly or wired, so weights go into SPC software or Excel without retyping. This page lists the Ohaus models in the System Builder and the cable each one needs.
Find your Ohaus gage in the builderOr describe your application to the System Advisor
Counts come from the MicroRidge Measurement Collection System Builder and update when the gage data does.
Does your Ohaus have RS-232?
Some Ohaus lines have RS-232 built in, such as Explorer balances and Defender 5000 indicators. Others need an Ohaus interface kit fitted first: the Scout, Navigator, Ranger 3000 and Valor 7000 offer RS-232 kits, and a Scout or Navigator fitted with the USB kit instead cannot connect to an RS-232 interface. Ohaus’s RS-232 kit for the Scout ends in a DB9 female plug, and the builder specifies the right DB9 cable for each model’s port.
| Gage connection | Models | Wireless (MobileCollect) | Wired (GageWay) |
|---|---|---|---|
| RS-232, DB9 male | 36 |
| |
| Ask MicroRidge | 7 | Ask MicroRidge | Not offered |
| DB9F-AS01709 | 4 |
|
|
| RS-232, DB9 | 3 | Ask MicroRidge | Not offered |
| RS-232, DB9 male, null modem | 2 |
|
|
| RS-232, Terminal Block | 2 | Ask MicroRidge | Not offered |
| RS-232, DB9 female | 1 | Ask MicroRidge | Not offered |
| RS-232, 8-pin DIN female | 1 | Ask MicroRidge | Not offered |
| RS-232, Wiring Block | 1 | Ask MicroRidge | Not offered |
Prices are U.S. list. The builder adds the base receiver or GageWay interface for your computer and checks each model.
Settings that matter
- Serial settings. Ohaus manuals for the Ranger 3000, Valor 7000 and Scout kit give a default of 9600 baud, 8 data bits, no parity, no handshake. The RS-232 Remote detects the baud rate automatically, and the RS-232 V2 Mobile Module supports 1,200 to 14,400 baud.
- Print mode. Ohaus Auto Print offers Off (print key only), On Stable, Interval and Continuous. For SPC data, use the print key or On Stable so each weight is a single, settled reading. If a scale streams continuously, the RS-232 Remote can gate the stream so only the reading you trigger is kept. See RS-232 Remote read switches.
- Stable weights only. On models such as the Ranger 3000 and Valor 7000, Ohaus marks an unstable weight with a question mark in the output. Wait for stable, and set the unit and tare before collecting, since both appear in the data.
Wireless or wired
The RS-232 Remote is the common choice for a bench scale: USB powered, it plugs into the scale’s serial port and sends each weight to a MobileCollect base. The RS-232 V2 Mobile Module runs on a battery for scales that move. A GageWay Pro takes a scale through the GW-LC level converter at a station with other gages. The RS-232 white paper and our guide to null modem versus straight-through cables cover the cabling.
Ohaus models in the builder
Scales and balances 37
| Series | Gage types | Models | Connection |
|---|---|---|---|
| Other | Balance Scale, Bench Scale, Balances | 37 | RS-232, DB9 male, DB9F-AS01709; 1 without data output |
Indicators 16
| Series | Gage types | Models | Connection |
|---|---|---|---|
| Other | Indicator, CD 11 Indicator | 16 | RS-232, DB9 male, RS-232, DB9 male, null modem, RS-232, Terminal Block |
Other gages 5
| Series | Gage types | Models | Connection |
|---|---|---|---|
| Other | Conductivimeter, Water Analysis Meter, Moisture Analyzer | 5 | RS-232, DB9, RS-232, DB9 female, RS-232, DB9 male |
Questions
Yes. A Wedge Base EVO, or a WedgeLink keyboard wedge on the scale’s serial port, types each weight into the active cell. Set Auto Print to Off and press Print, or use On Stable. See the Excel guide to keyboard wedge input. Not over USB. The scale needs Ohaus’s RS-232 interface, either built in or as a kit, to connect to an RS-232 interface. Search the model in the System Builder. It lists the transmitter and the DB9 cable for that model’s port, with its serial settings.Can an Ohaus scale send weights straight into Excel?
My Ohaus has a USB port. Can MicroRidge read it?
Which cable does my Ohaus model need?
Every Ohaus model in the builder
Select a model to open it in the System Builder with the transmitter, cable and base, along with its port and serial settings.
Scales and balances
Other: (EX)Explorer - after 2013, Adventure Pro - AV Series, Adventurer (2005), Adventurer (2014), Adventurer - AR Series, Adventurer - AX Series, Adventurer Pro, Discovery, Discovery Series, Explorer (before 2013), Explorer Pro, Explorer Series - after 2013, Explorer Series - before 2013, Navigator, Navigator Series, NLV Series, NV / NVT, Pioneer - PA Series, Pioneer - PX Series, PR Series, Ranger 3000, Ranger 3000 Series, Ranger 4000, Ranger 7000, Ranger 7000 Series, Scout - red case, Scout Pro, Scout Pro - blue case, Scout SJX, Scout SKX, Scout SPX, Scout ST3110M, Scout STX, Traveler, Traveler Series, Voyager Pro balances
Indicators
Other: CD11, CD Series, Defender 5000 TP51P, Defender 5000 TP51XW, Defender 5000 TP52P, Defender 5000 TP52XW, I10, T31P, T31XW, T32MC, T32ME, T32XW, T51P, TD51XW, TD52P, TD52XW
Other gages
Other: 3100 / 2100 / 3100C, a-AB33EC, a-AB33EH, a-AB33M1, MB45_MB90_MB120
Scales and balances without data output: ES Series. These models have no data output, so no cable or transmitter can read them.