Introduction

Ordering the wrong Mitutoyo SPC cable is a recurring sourcing error that grounds inspection stations, delays production, and is entirely avoidable. The Digimatic protocol is consistent across most of the Mitutoyo instrument lineup, but the physical connector on the gage side varies significantly by instrument family. One connector type is compatible with your 500-series Absolute caliper; a completely different one fits your micrometer; another is required for your ID-C indicator. And if your ID-C was purchased after 2023, neither of those is correct.

Every gage covered in this guide can be connected to either a GageWay wired interface or a MobileCollect wireless system — the cable determines the gage-side connection, not the data collection path. This guide organizes every current Mitutoyo Digimatic SPC cable by physical connection group, maps each group to its applicable gage series, and identifies which cables include a data-send button. Use it as a definitive sourcing reference before your next purchase order.

Note: The cable part numbers in this guide apply to the standard Digimatic data output path used with GageWay wired interfaces. If you are sourcing cables for a third-party gage interface, the GageWay wired cable part numbers (905338, 959149, 937387, etc.) are the correct OEM Mitutoyo references to follow. MobileCollect Wireless connector cables are MicroRidge-specific and are not compatible with other gage interfaces. If you are connecting MobileCollect to a Mitutoyo DP-1VA Logger, see the MobileCollect to DP-1VA adapter. If you are sourcing cables for Mitutoyo’s USB Input Tool Direct (USB-ITN) or U-WAVE-T wireless system, the physical connector types are the same but the SKUs differ — refer to the current Mitutoyo catalog or contact MicroRidge for the correct part numbers.


The Digimatic Protocol vs. The Connector: Understanding the Difference

Before mapping cables to gages, two distinctions matter. First, Mitutoyo Digimatic SPC output exists in two protocol variants: D1 (standard Digimatic, used across all current instrument families except the NX-series) and D2 (higher-resolution packet format, exclusive to NX-series ID-C and ID-F indicators). D1 and D2 differ at the data packet level — they are not interchangeable at the protocol layer, though both are read by the same GageWay and MobileCollect interfaces. Second, and independently of the protocol variant, the physical connector on the gage side varies significantly by instrument family. Most sourcing errors trace to the connector, not the protocol — but both matter.

This matters for infrastructure planning: GageWay wired interfaces and MobileCollect wireless transmitters are parallel data collection paths — not combinable on the same signal chain — and the correct choice depends on whether your measurement stations are fixed or portable, not on gage type. Either path can serve the full Mitutoyo instrument lineup.

The connector architecture differs by interface family. GageWay interfaces (SM, KW, Pro) and the MobileCollect Digital Remote accept standard OEM Mitutoyo SPC cables directly at a standard Digimatic header — the part numbers in this guide apply directly. MobileCollect transmitters use proprietary MicroRidge pigtail connectors on the gage side; the Mini Mobile Module EVO (M3E) and Command Mobile Module use different proprietary connectors and are not cross-compatible with each other or with standard OEM Mitutoyo cables. MobileCollect cables are ordered by transmitter model and gage type through MicroRidge. The gage-side connector type is what determines which cable you need regardless of which interface path you choose.


Complete Connector Type Reference

The following table summarizes every current connector type from Mitutoyo’s SPC cable compatibility chart, with part numbers for both 1-meter (40″) and 2-meter (80″) lengths.

Type
Form Factor
Data Button
Output Protocol
Part Number
Primary Gage Category
A
Straight water-proof with output button
Yes
Digimatic
05CZA624
1 meter
05CZA625
2 meter
IP-rated Digimatic calipers
B
Flat L-Shape water-proof with output button
Yes
Digimatic
05CZA662
1 meter
05CZA663
2 meter
IP-rated Digimatic instruments (micrometers)
C
Straight with output button
Yes
Digimatic
959149
1 meter
959150
2 meter
Digimatic calipers (Absolute encoder)
CR
L-shape, outlet right with output button
Yes
Digimatic
04AZB512
1 meter
04AZB513
2 meter
micrometers, right-exit variant, custom implementations
D
Flat 10-pin
No
Digimatic
936937
1 meter
965014
2 meter
Micrometers (standard & IP), indicators, scale units
E
Round 6-pin
No
Digimatic
937387
1 meter
965013
2 meter
Standard micrometers, Holtest, Borematic, Bench Mike
F
905338 Connector
Flat straight
No
Digimatic
905338
1 meter
905409
2 meter
Indicators, height gages, depth gages, scale units, thickness gages
FB
905338 connector but L-shaped with outlet in the back.
No
Digimatic
905689
1 meter
905690
2 meter
Indicators, height gages (back-exit variant)
FR
L-shape, outlet right
No
Digimatic
905691
1 meter
905692
2 meter
Indicators, height gages (right-exit variant)
FL
L-shape, outlet left
L-shape, outlet left
No
Digimatic
905693
1 meter
905694
2 meter
Indicators, height gages (left-exit variant)
G
Flat straight, water-proof
No
Digimatic
21EAA194
1 meter
21EAA190
2 meter
ID-N/ID-B coolant-proof indicators
SA
Water-proof, straight with output button
Yes
Digimatic D2 + S1
06AGL111
1 meter
06AGL121
2 meter
MDE QuantuMike Series 293 (2024+)
SF
Flat straight standard
No
Digimatic D2 + S1
06AGL011
1 meter
06AGL021
2 meter
NX-series ID-C/ID-F indicators (2023+)

D2 = higher-resolution output (to 0.5 µm / 20 µin) — active now on any GageWay or MobileCollect interface running firmware v5.35+. S1 = instrument-level query protocol; unlike standard Digimatic (which can only request a measurement reading), S1 allows the interface to query the gage directly for instrument metadata such as serial number, model, and calibration data. S1 query capability requires both the 06AGL011/06AGL111 cable and an NX-series gage — it is not available on any other cable type. MicroRidge’s GageSync feature (coming Q3 2026, M3E only) will be the first interface implementation to surface S1 instrument data. MobileCollect firmware v5.35+ required for D2 output; transmitters shipped after June 2023 include this by default.


Connection Group 1: Types C, F, CR, and Angled F Variants

Cables in this group: 905338 · 959149 · 04AZB512 · 905689 · 905691 · 905693

All cables in this group share the same physical gage-side Digimatic connector and are physically interchangeable at the gage port. The differences are cable geometry (straight vs. angled exit) and whether a data-send button is present — not the connector itself. All use Digimatic D1 protocol.

Cable
Button
Exit
Primary Use
905338 (1m) / 905409 (2m)
No
Straight
Indicators, height gages, depth gages, scale units, thickness gages
959149 (1m) / 959150 (2m)
Yes
Straight
Absolute Digimatic calipers, operator-triggered read stations
04AZB512 (1m) / 04AZB513 (2m)
Yes
L-shape, right exit
Calipers where right-angle cable routing is required
905689 (1m) / 905690 (2m)
No
L-shape, back exit
Indicators, height gages mounted with back cable exit
905691 (1m) / 905692 (2m)
No
L-shape, right exit
Indicators, height gages mounted with right cable exit
905693 (1m) / 905694 (2m)
No
L-shape, left exit
Indicators, height gages mounted with left cable exit

On interchangeability: Because the gage-side connector is identical across this group, a 959149 will physically mate with an indicator that normally takes a 905338, and vice versa. The button is the deciding factor for workflow — indicator stations typically rely on foot switch or interface-triggered reads, while caliper stations frequently use the data-send button for operator-controlled read cycles. Using a 959149 on an indicator is functional but suboptimal; using a 905338 on a caliper means the operator loses the button and must use a foot switch or hand switch instead. Match the cable to the workflow, not just the connector.

Applicable instruments — 905338 / angled no-button variants:

  • Digimatic Indicators (Series 543): 543-200, 543-202, 543-212, 543-251, 543-400, 543-402, 543-472B, 543-492B, and related ID-C / ID-F / ID-S models with the Type F port
  • Height Gages (Series 570/192): 570-244, 570-312, 570-314, 192-630, 192-632, 192-670, 192-671, and related
  • Depth Gages (Series 571): 571-251, 571-253, 571-257
  • Thickness Gages (Series 547): 547-211, 547-251, 547-300, 547-400
  • Scale Units (Series 572): 572-600, 572-601
  • Older calipers without Absolute encoder (500-series, 530-series)

Applicable instruments — 959149 / button variants:

  • 500-series Absolute Digimatic Calipers: 500-150-30, 500-151-30, 500-152-30, 500-170-30, 500-171-30, 500-172-30, 500-173-30, 500-181-30, 500-182-30, 500-191-30, 500-197-30, 500-443-10, 500-501-20, and related
905338 Connector
905338
L-shape, outlet left
905693
959149

Connection Group 2: Water-Proof Digimatic — Types A and B

Cables in this group: 05CZA624 · 05CZA662

Types A (05CZA624) and B (05CZA662) share the same water-proof Digimatic connector and are physically interchangeable at the gage port. Both include a data-send button and are designed for IP-rated instruments in wash-down, coolant-exposure, or high-humidity environments. The distinction between them is which instrument family each is specified for — calipers vs. micrometers.

Cable
Primary Use
05CZA624 (1m) / 05CZA625 (2m)
Coolant-proof Digimatic calipers
05CZA662 (1m) / 05CZA663 (2m)
Coolant-proof Digimatic micrometers

Applicable instruments — 05CZA624 (calipers and related):

  • Digimatic calipers: 500-776/500-777, 500-712-20/500-713-20, and related 500-712 series
  • Coolant-proof calipers: 550-301-10/550-331-10, 551-301-10/551-331-10
  • IP67 calipers: 552-302-10/552-303-10, 552-150-10/552-151-10, 552-155-10/552-156-10, 552-181-10/552-182-10
  • Digimatic indicators: 573-601/573-602, and related
  • Digimatic depth gage: 571-251-10/571-252-10, and related
  • Digimatic scale units

Applicable instruments — 05CZA662 (micrometers and related):

  • Digimatic micrometers: 293-140-30/293-141-30, 293-230-30 series, 340-251-30/340-252-30, 293-666-20/293-667-20
  • Coolant-proof micrometers: 227-201-20/227-203-20, 227-205-20/227-206-20, 227-221-20, 227-223-20
  • Digimatic micrometers: 422-230-30/422-231-30, 406-250-30/406-251-30, 343-250-30/343-251-30, 369-250-30/369-251-30, 345-250-30/345-251-30, 314-251-30/314-252-30
  • Digimatic micrometer heads: 350-251-30/350-261-30, and related
  • Digimatic Holtest: 468-161/468-162, and related
  • Digimatic depth gages: 329-250-30/329-251-30, and related
  • Digimatic scale units: 572-600/572-601, and related

On interchangeability: Because the gage-side connector is identical between Type A and Type B, either cable will physically mate with any instrument in this group regardless of the specified designation. If your measurement station layout makes one cable’s geometry more practical — a micrometer in a fixed stand where the caliper-specified cable routes more cleanly, for example — the swap is physically and electrically valid. Both carry the same D1 Digimatic protocol and data-send button circuit.

05CZA662
05CZA624

Connection Group 3: Round 6-Pin Digimatic — Type E

Cable: 937387 (1m) / 965013 (2m) — No data-send button.

The 937387 is the SPC cable for standard Mitutoyo Digimatic micrometers. The round 6-pin connector (Type E) is physically distinct from the flat connectors in all other groups — there is no cross-compatibility. No other cable in this guide mates with a Type E port.

Applicable instruments:

  • Standard Digimatic micrometers: 293-140-30, 293-141-30, 293-230-30, 293-240-30, 293-252-30, 293-330-30, 293-340-30, 293-350-30, 293-360-30, and related (non-IP65)
  • Select ID-S indicators: 543-110, 543-130, 543-140, 543-170, 543-180
  • Holtest: 468-200, 468-210, 468-900 series
  • Borematic: 568-series
  • Bench Mike: 121-series
  • Micrometer heads: 164-162, 164-172, 350-710, 329-710
  • Mikematic and QuickMike
  • Select 389-series: 293-582, 293-583, 389-514, 389-714 — verify in Mitutoyo catalog

Reads are triggered by foot switch or interface. For micrometer-heavy inspection stations, foot switch is standard practice — both hands remain on the workpiece during measurement.

937387

Connection Group 4: Flat 10-Pin Digimatic — Type D

Cable: 936937 (1m) / 965014 (2m) — No data-send button.

The 936937 covers Mitutoyo micrometers and select precision instruments using a flat 10-pin Digimatic connection. The Type D gage-side shell geometry differs from Group 1 despite a similar appearance — the two are not physically interchangeable.

Applicable instruments:

  • Digimatic micrometers: 293-660-30 through 293-687-30 series and related
  • Digimatic Indicators (Series 573): 573-110 through 573-119, 573-181 through 573-192 (select models — verify in catalog)
  • Micrometer heads: 164-163, 164-164
  • Digimatic micrometer heads: 350-251 through 350-253, 345-250 through 345-251, 314-251 through 314-252
  • Scale units: 572-200 through 572-213, 572-300 through 572-301

For the full series list, cross-reference the Type D column in the Mitutoyo Compatibility Lists of Digimatic Gages and Connecting Cables.

936937

Connection Group 5: Coolant-Proof Flat Digimatic — Type G

Cable: 21EAA194 (1m) / 21EAA190 (2m) — No data-send button.

The 21EAA194 is the SPC cable for Mitutoyo’s ID-N and ID-B indicators — the coolant-proof (IP66) variants of the standard indicator series. Common in machine-side applications where cutting fluid exposure is a design constraint. The water-sealed gage-side connector is unique to this group; the Digimatic D1 output is standard and compatible with all GageWay and MobileCollect interfaces.

Applicable instruments:

  • Digimatic Indicator ID-N series
  • Digimatic Indicator ID-B series
21EAA194

Connection Group 6: NX-Series SF Connector — Types SF and SA

Cables in this group: 06AGL011 · 06AGL111

The 06AGL011 (Type SF, no button) and 06AGL111 (Type SA, water-resistant with button) share the same NX-series SF gage-side connector and are physically interchangeable at the gage port. Their primary use cases are distinct — the 06AGL011 is specified for NX-series indicators, while the 06AGL111 is the primary cable for the Mitutoyo MDE QuantuMike Series 293 Coolant Proof IP65 Micrometers. Because they share the same physical connection, the 06AGL111 can also serve as the only option for an NX-series indicator application where an operator data-send button is required, though its water-resistant shell and retention screws make it less convenient in that context.

Cable
Button
Exit
Primary Use
06AGL011 (1m) / 06AGL021 (2m)
No
Standard – flat straight
NX-series ID-C/ID-F indicators (543-70X, 543-71X, 543-72X, 543-73X)
06AGL111 (1m) / 06AGL121 (2m)
Yes
Water-proof with retention screws – flat straight
MDE QuantuMike Series 293 Coolant Proof IP65 Micrometers

This group is not interchangeable with any other connection group. The SF connector will not mate with a pre-NX indicator or any standard Digimatic instrument that uses a Group 1 through 5 connector, and vice versa. This is a deliberate physical break — Mitutoyo changed the connector specifically to support D2 and S1 protocol capabilities that the previous connector geometry could not reliably carry.

The SF connector arrived on two separate instrument families at different times. In 2023, Mitutoyo introduced the NX-series ID-C and ID-F Digimatic indicators — Series 543-70X, 543-71X, 543-72X, and 543-73X — replacing the Type F port with the new SF connector. In 2024–2025, Mitutoyo extended the SF connector to the QuantuMike Series 293 Coolant Proof IP65 Micrometers. Both instrument families use the same physical connection and are served by the same cable group, but if you purchased a QuantuMike before the connector update you may still have the previous cable type — verify before ordering. Both transitions introduced two protocol capabilities not present on any other connection group:

Digimatic D2 delivers higher-resolution measurement output — down to 0.5 µm / 20 µin — and represents a meaningful step forward in precision data collection. D2 is fully supported across the MicroRidge lineup, including all GageWay wired interfaces and MobileCollect wireless transmitters.

Digimatic S1 is a true instrument-level query protocol — qualitatively different from standard Digimatic. Where standard Digimatic is unidirectional (the interface asserts REQ, the gage outputs a measurement reading, transaction complete), S1 allows the interface to query the instrument directly for metadata: serial number, model identification, calibration data. This enables traceability at the instrument level, not just the measurement level — the data collection system can verify which instrument produced a reading, not just record the value.

GageSync, MicroRidge’s S1 implementation, is scheduled for Q3 2026 on the Mini Mobile Module EVO (M3E). It will be the first MicroRidge interface to surface S1 instrument data to your SPC or quality management system. If your traceability requirements extend to instrument-level data, the 06AGL011 and M3E are the correct hardware to deploy now ahead of the GageSync release.

How to identify a Group 6 instrument:

  • NX-series indicators: series code 543-70X, 543-71X, 543-72X, or 543-73X; purchased or delivered 2023 or later
  • QuantuMike IP65 micrometers: Series 293 Coolant Proof models updated 2024–2025
  • For either family: the SPC port will not accept any Group 1 through 5 connector

For a full breakdown of the shift to the SF connector, what changed, and which instruments are affected, read the complete guide here: Mitutoyo SPC Cable Connector Changes: 06AGL011, 06AGL111, and the NX-Series Shift.

06AGL011 Connector
06AGL011
06AGL111 Connector
06AGL111

Connecting to SPC Software, Excel, etc: What Happens After the Cable

Selecting the correct cable resolves the gage-side connection. The other end of the signal path — from cable to SPC software — is where MicroRidge interfaces come in.

Wired data collection (GageWay):
The GageWay product line accepts all Digimatic SPC cable types and outputs measurement data via virtual COM port (GageWay SM) or as keyboard wedge keystrokes directly into Excel, cloud-based SPC, or any accepting application (GageWay KW) — no additional software required. GageWay Pro supports multi-gage configurations and also outputs via keyboard wedge and COM port, making it the wired option for multi-station inspection cells feeding a single SPC application. No baud rate configuration or communication parameters are required — Digimatic is pre-configured.

Wireless data collection (MobileCollect RM2.4):
MobileCollect replaces the wired cable-to-interface run with a wireless RM2.4 link operating on IEEE 802.15.4 at 32-bit encryption. The Mini Mobile Module EVO M3E transmitter attaches directly to the gage via a MobileCollect cable connector (the short pigtail that replaces the wired SPC cable). A MobileCollect Base Receiver connects to the workstation and presents data to your SPC software on a virtual COM port or as keyboard wedge keystrokes directly into Excel, cloud-based SPC, or any accepting application, without additional software.

MobileCollect runs on RM2.4 — an industrial-grade wireless protocol built specifically for transferring measurement data from precision instruments on the shop floor. Where Bluetooth and Wi-Fi introduce interference, dropped readings, and security gaps in manufacturing environments, RM2.4 operates on IEEE 802.15.4 with 32-bit encryption, purpose-designed for reliable gage data collection.

→ Why RM2.4 outperforms Bluetooth in manufacturing

Finding MobileCollect wireless cable part numbers: The wireless connector part numbers for each gage type are listed under the Wireless Options section on the corresponding OEM cable product pages. Start with the OEM cable that matches your gage’s connection group, then find the wireless equivalent in the Wireless Options section. For example, the 905338 product page lists the compatible MobileCollect Wireless connectors for each MobileCollect transmitter model. The MobileCollect Selection Tool can also be used to find the MobileCollect Wireless part numbers. 

Decision framework:

  • Fixed measurement station, single gage → GageWay SM or KW
  • Fixed station, multiple gages → GageWay Pro
  • Portable or machine-side inspection → MobileCollect Mini Mobile Module EVO
  • Remote read triggering (REQ initiated from Base or SPC software, no operator button press) → Digital Remote (wired) or Command Mobile Module (wireless)
  • S1 instrument-level query — serial number, model, calibration data — from NX-series indicators → M3E + 06AGL011 cable, GageSync feature Q3 2026

Not Sure Which Cable Your Gage Uses?

Use the MobileCollect Selection Tool to search by gage model number or OEM part code. The database indexes 3,500+ gages including Mitutoyo instruments with connector type, recommended MicroRidge cable, and compatible interface pre-mapped.

The gage code is typically printed on the back or bottom of the instrument. Enter it directly into the Selection Tool, or contact us at sales@microridge.com to confirm the correct cable and interface configuration for your specific measurement station layout.


Frequently Asked Questions

Can I use a 959149 on an indicator that normally takes a 905338?
Physically, yes — both are Group 1 cables and share the same gage-side connector. The 959149 will mate with any indicator that takes the 905338. In practice, the data-send button on the 959149 is simply unused in that application. The more common issue is the reverse: using a 905338 on a caliper station where the operator expects a button-triggered read cycle. That works electrically but changes the workflow — reads must come from a foot switch or the interface instead.

My indicator is a Series 543 — how do I know if it takes the 905338 or the 06AGL011?
Check the series code on the instrument. Pre-2023 ID-C and ID-F indicators (543-200 through 543-6XX range) use the 905338 Group 1 connector. NX-series indicators introduced in 2023 (543-70X, 543-71X, 543-72X, 543-73X) use the 06AGL011 Group 6 SF connector. The two connectors are not physically interchangeable — if the cable won’t seat, you have the wrong group. Use the MobileCollect Selection Tool to confirm by model number.

I have a mixed gage floor — some micrometers, some calipers, some indicators. Do I need a different interface for each cable type?
No. All connection groups feed the same Digimatic protocol into your GageWay or MobileCollect interface. GageWay Pro supports multi-gage configurations across mixed cable types on a single interface. MobileCollect handles mixed fleets wirelessly with each transmitter paired to its gage regardless of cable group. Group 6 instruments with D2 output are fully supported across the MicroRidge lineup.

What’s the difference between the 05CZA624 and 05CZA662 — can I use either on my IP-rated gage?
Both are Group 2 cables with the same water-resistant gage-side connector, so either will physically mate with any instrument in the group. The 05CZA624 is specified for coolant-proof calipers; the 05CZA662 for coolant-proof micrometers. If your measurement station layout makes one cable’s geometry more practical than the other, the swap is electrically valid.

What does “S1” actually mean for my data collection setup — and does it work today?
S1 is an instrument-level query protocol supported by NX-series indicators (via the 06AGL011) and QuantuMike IP65 micrometers (via the 06AGL111). Where standard Digimatic is a one-way transaction (REQ → measurement reading), S1 allows the interface to query the gage directly for instrument metadata: serial number, model identification, calibration data. This enables traceability at the instrument level, not just the measurement level. MicroRidge’s GageSync feature, which surfaces this data through the M3E transmitter, is scheduled for Q3 2026. D2 (higher-resolution measurement output) is a separate capability from S1 and is active now across the full MicroRidge lineup.

Can I extend cable length?
Yes — the G-EXT extension cable adds 8 feet of in-line length between any Digimatic SPC cable and your interface, without signal degradation.

MicroRidge is a Certified Mitutoyo Distributor. All cable types referenced in this guide are OEM Mitutoyo products sold through MicroRidge. For instruments not listed or recently introduced models, contact us at sales@microridge.com for cable type verification before ordering.

Picture of Riley Tronson

Riley Tronson

Riley Tronson is President and owner of MicroRidge Systems, a role held since 2023. Riley brings a strong technical foundation to leadership in measurement solutions. An experienced entrepreneur, Riley has founded and grown multiple software companies, including a venture focused on developing iPhone applications, blending engineering expertise with innovative product development.

Explore more metrology guides!

Leave a Reply

Your email address will not be published. Required fields are marked *