Most Fowler electronic gages, including the Fowler Sylvac line built with Swiss Sylvac electronics, use Sylvac’s family of data ports rather than Digimatic, and a few models use Mitutoyo-style Digimatic cables. Which port a gage has depends on its generation, so two Fowler calipers can need different connectors. This page shows the connection for every Fowler model in the System Builder.
Find your Fowler gage in the builderOr describe your application to the System Advisor
Counts come from the MicroRidge Measurement Collection System Builder and update when the gage data does.
Fowler data ports
- Opto RS-232, simplex (54-115-333). An opto-coupled serial port on many Ultra-Cal and Ultra Light calipers, Mark IV and Mark V indicators, depth gages and indicating micrometers. Simplex means the gage sends readings and does not take commands.
- Opto RS-232, duplex (54-115-336). The same port with two-way communication, so the computer can request a reading or send commands. MicroRidge’s duplex connectors fit the same gages as the simplex ones.
- Proximity (54-115-527). Sylvac’s newer connector, on Ultra-Cal VI Proximity calipers, Ultralight IV calipers, Rapid-Mic micrometers and XTH3/XTD3 bore gages.
- Power style (54-115-444). On S_Dial One and Mini electronic indicators, electronic test indicators and S-Depth gages.
The Fowler part numbers above are the cables Fowler sells for each port. MicroRidge offers the MobileCollect connector for each one and RS-232 versions for the RS-232 Remote and GageWay Pro. Opto outputs are low voltage, so they connect wirelessly through the Mini Mobile Module EVO rather than the RS-232 V2 module.
| Gage connection | Models | Wireless (MobileCollect) | Wired (GageWay) |
|---|---|---|---|
| 54-115-333 Series 54, ULTRA, EURO | 80 |
| |
| 54-115-527 Series 54, ULTRA | 49 |
| |
| 54-115-444 Series 54 | 17 |
| |
| 905338 Series 54 | 7 |
| |
| 22806-MIT Series 54 | 7 |
|
|
| 959149 Series 54 | 6 |
| |
| Ask MicroRidge Series 54 | 6 | Ask MicroRidge | Not offered |
| RS-232, DB9 male Series 54 | 6 |
| |
| RS-232, DB9 female, null modem | 3 |
|
|
Prices are U.S. list. The builder adds the base receiver or GageWay interface for your computer and checks each model.
Check the part number for output
Fowler sells many gages with and without output, and in the current Ultra-Cal VI line the part number tells you which port a caliper has: some numbers have Bluetooth built in, others use the proximity cable, and others have no output. The builder lists each model, and models without output are at the bottom of this page.
MobileCollect or Bluetooth
Many current Fowler Sylvac gages have Bluetooth built in and pair with Fowler’s USB Bluetooth receiver. MobileCollect is the choice when a floor mixes Fowler gages with other brands, when gages sit behind metal or among machines, or when more gages need to report to one computer. The RM2.4 versus Bluetooth white paper compares range and battery life, including the Fowler/Sylvac S_Cal EVO.
For fixed stations, RS-232 Fowler gages connect to an RS-232 Remote or a GageWay Pro channel through the GW-LC level converter.
Fowler series in the builder
Calipers 78
| Series | Gage types | Models | Connection |
|---|---|---|---|
| 54 | Ultra-Cal VI, Internal Electronic Caliper, External Electronic Caliper | 72 | 54-115-333, 54-115-527, 22806-MIT; 30 without data output |
| Other | Caliper | 2 | 54-115-333 |
| ULTRA | Caliper | 2 | 54-115-333, 54-115-527 |
| EURO | Caliper | 1 | 54-115-333 |
| PRO | Caliper | 1 | 54-115-333 |
Indicators 55
| Series | Gage types | Models | Connection |
|---|---|---|---|
| 54 | Mark VI Indicator, Mark IV Indicator, S_Dial One Indicators | 48 | 54-115-527, 54-115-333, 54-115-444; 4 without data output |
| Other | Indicator | 5 | 54-115-333, 54-115-444 |
| ULTRA | Indicator | 2 | 54-115-333 |
Micrometers 35
| Series | Gage types | Models | Connection |
|---|---|---|---|
| 54 | Micrometer, IP54 Micrometer - USB output, IP54 Blade Micrometer | 33 | 54-115-527, 54-115-333, 905338; 17 without data output |
| Other | Micrometer | 2 | 54-115-333, 54-115-527 |
Height gages 30
| Series | Gage types | Models | Connection |
|---|---|---|---|
| 54 | Mini-Vertical Series II, Digital Ultra-Height Gages, Vertical Scale | 16 | 54-115-333, RS-232, DB9 male, 54-115-527; 2 without data output |
| Other | Height Gage | 14 | 54-115-333, RS-232, DB9 male, RS-232, DB9 female, null modem; 1 without data output |
Other gages 19
| Series | Gage types | Models | Connection |
|---|---|---|---|
| 54 | Ultra-Light Mark III, Gage output not supported, MicroGage | 17 | 54-115-333, 54-115-527; 7 without data output |
| Other | Gage output not supported, Discontinued item | 2 | 1 without data output |
Depth gages 10
| Series | Gage types | Models | Connection |
|---|---|---|---|
| 54 | Depth Gage, Sylvac Euro-Depth Gage, Sylvac Depth Gage | 9 | 54-115-333; 3 without data output |
| Other | Depth Gage | 1 | 54-115-333 |
Bore gages 10
| Series | Gage types | Models | Connection |
|---|---|---|---|
| Other | Holemike, Digital Holemike - OPTO, Digital Holemike - PROX | 10 | 54-115-527, 54-115-444, 54-115-333 |
Scales and balances 9
| Series | Gage types | Models | Connection |
|---|---|---|---|
| 54 | Scale, Horizontal Scale | 9 | 54-115-333 |
Thickness gages 2
| Series | Gage types | Models | Connection |
|---|---|---|---|
| 54 | Digital Thickness Gage, Xtra-Value Digital Thickness Gage | 2 | 2 without data output |
Questions
Yes. A simplex cable reads a duplex gage, but the gage ignores commands from the computer. Use the duplex cable when your software needs to request readings or change gage settings. Yes. One MobileCollect base takes readings from every transmitter, and a GageWay Pro reads Digimatic and RS-232 gages side by side. Only the connector on each gage changes. Search the model number in the System Builder. It lists the connector, transmitter and base, or tells you the model has no output.Will a simplex opto cable work on a duplex gage?
Do Fowler gages work on the same system as my Mitutoyo gages?
How do I find the right connector for my Fowler gage?
Every Fowler model in the builder
Select a model to open it in the System Builder with the transmitter, cable and base.
Indicators
Other: Dialmatic, Mini Resist, QuadraTest, Series 213, Ultra Digit Mini
54 series: 54-520-305-0, 54-520-310-0, 54-520-320-0, 54-520-555, 54-520-600, 54-520-605, 54-520-610, 54-520-680-1, 54-520-680-2, 54-520-680-3, 54-520-777, 54-520-790, 54-520-791, 54-520-792, 54-520-794, 54-520-875, 54-520-876, 54-520-888, 54-520-900, 54-520-905, 54-530-124, 54-530-125, 54-530-134, 54-530-135, 54-530-136, 54-530-137, 54-530-144, 54-530-145, 54-530-154, 54-530-155, 54-530-156, 54-530-157, 54-530-164, 54-530-174, 54-530-175, 54-530-195, 54-530-215, 54-530-335, 54-530-355, 54-530-535, 54-530-555, 54-530-630, 54-562-777, 54-562-888
ULTRA series: Ultra-Digit Mark IV, Ultra-Digit Mark V
Calipers
Other: S_Cal, Ultra Cal III
54 series: 54-100-000-2, 54-100-004-2, 54-100-008-2, 54-100-012-0, 54-100-020-0, 54-100-040-0, 54-100-067-1, 54-100-067-C, 54-100-068-1, 54-100-069-1, 54-100-080-0, 54-100-112-2, 54-100-212, 54-100-330, 54-100-340, 54-100-400, 54-100-412-0, 54-100-412-1, 54-100-444-0, 54-100-444-1, 54-100-448-0, 54-100-448-1, 54-100-712-2, 54-100-777-2, 54-110-512, 54-110-540, 54-110-560, 54-110-580, 54-110-600, 54-110-650, 54-112-100-0, 54-112-300-0, 54-112-600-0, 54-200-777, 54-200-888, 54-554-005-2, 54-554-010-2, 54-554-012-2, 54-554-013-2, 54-554-030-2, 54-554-050-2, 54-554-070-2
EURO series: Euro-Cal III
PRO series: Pro-Max
ULTRA series: Ultra-Cal IV, Ultra-Cal V
Height gages
Other: Digital Ultra, Hi CAL, Mestra-Touch, MiniVertical Series II, Trimos Mestra, Trimos Mestra Touch, Trimos TVM, Trimos V+ Series, Trimos Vectra Plus, Trimos V Series, Vectra-Touch, Vertical 500A, Z_Cal 350 / 600
54 series: 54-050-025, 54-050-035, 54-105-012-0, 54-105-024-0, 54-105-040-0, 54-180-212-0, 54-180-215-0, 54-180-224-0, 54-180-226-0, 54-212-016-1, 54-212-024-1, 54-931-150-0, 54-931-300-0, 54-931-450-0
Micrometers
Other: S_Mike, S_Mike Pro
54 series: 54-245-777, 54-245-780, 54-245-800, 54-245-825, 54-815-030-0, 54-815-060-0, 54-815-100-0, 54-815-110-0, 54-815-111-0, 54-815-112-0, 54-815-130-0, 54-815-160-0, 54-880-001-0, 54-880-002-0, 54-880-003-0, 54-880-004-0
Other gages
Other: S_Dial One Indicator
54 series: 54-110-312, 54-110-324, 54-110-340, 54-110-360, 54-150-012-0, 54-551-001-0, 54-551-002-0, 54-551-003-0, 54-551-004-0, 54-866-XXX
Bore gages
Other: Mark II, XT (not xtreme), XT3 Series, XT500 Series, XTD3 Series, XTD Series, XTH3 Series, XTH Series, XTL Series, XT xtreme
Scales and balances
54 series: 54-050-004, 54-050-005, 54-050-013, 54-050-015, 54-998-108, 54-998-120, 54-998-124, 54-998-130, 54-998-140
Depth gages
Other: Depthmatic
54 series: 54-137-008, 54-137-012, 54-138-012, 54-138-020, 54-275-065, 54-275-100
Calipers without data output: 54-100-024-1, 54-100-042-1, 54-100-100-0, 54-100-167-0, 54-100-167-C, 54-100-168-0, 54-100-169-0, 54-100-177-0, 54-100-178-0, 54-100-179-0, 54-100-312-0, 54-101-150-2, 54-101-200-1, 54-101-300-1, 54-103-006-0, 54-103-012-0, 54-550-000, 54-550-300, 54-554-611, 54-554-622, 54-554-623, 54-554-624, 54-554-625, 54-554-630, 54-554-711, 54-554-722, 54-554-723, 54-554-724, 54-554-725, 54-554-730-0. These models have no data output, so no cable or transmitter can read them.
Height gages without data output: 54-106-020-0, 54-106-040-0, Z-Height-E. These models have no data output, so no cable or transmitter can read them.
Other gages without data output: 54-115-778, 54-115-779, 54-150-004-0, 54-150-020, 54-175-012, 54-175-024, 54-554-930, Quadramic. These models have no data output, so no cable or transmitter can read them.
Depth gages without data output: 54-125-777, 54-225-456-0, 54-225-xxx. These models have no data output, so no cable or transmitter can read them.
Indicators without data output: 54-520-025-1, 54-520-250-0, 54-520-255-0, 54-520-260-0. These models have no data output, so no cable or transmitter can read them.
Thickness gages without data output: 54-550-500, 54-554-830-0. These models have no data output, so no cable or transmitter can read them.
Micrometers without data output: 54-815-001, 54-816-025-0, 54-860-001-1, 54-860-002-1, 54-860-003-1, 54-860-004-1, 54-860-005-1, 54-860-006-1, 54-860-211-0, 54-860-241-0, 54-860-242-0, 54-860-243-0, 54-860-244-0, 54-870-001-0, 54-870-002-0, 54-870-003-0, 54-870-004-0. These models have no data output, so no cable or transmitter can read them.