Most Fowler electronic gages, including the Fowler Sylvac line built with Swiss Sylvac electronics, use Sylvac’s family of data ports rather than Digimatic, and a few models use Mitutoyo-style Digimatic cables. Which port a gage has depends on its generation, so two Fowler calipers can need different connectors. This page shows the connection for every Fowler model in the System Builder.

248Fowler gage models in the builder
181with data output
9connection types

Find your Fowler gage in the builderOr describe your application to the System Advisor

Counts come from the MicroRidge Measurement Collection System Builder and update when the gage data does.

Fowler data ports

  • Opto RS-232, simplex (54-115-333). An opto-coupled serial port on many Ultra-Cal and Ultra Light calipers, Mark IV and Mark V indicators, depth gages and indicating micrometers. Simplex means the gage sends readings and does not take commands.
  • Opto RS-232, duplex (54-115-336). The same port with two-way communication, so the computer can request a reading or send commands. MicroRidge’s duplex connectors fit the same gages as the simplex ones.
  • Proximity (54-115-527). Sylvac’s newer connector, on Ultra-Cal VI Proximity calipers, Ultralight IV calipers, Rapid-Mic micrometers and XTH3/XTD3 bore gages.
  • Power style (54-115-444). On S_Dial One and Mini electronic indicators, electronic test indicators and S-Depth gages.

The Fowler part numbers above are the cables Fowler sells for each port. MicroRidge offers the MobileCollect connector for each one and RS-232 versions for the RS-232 Remote and GageWay Pro. Opto outputs are low voltage, so they connect wirelessly through the Mini Mobile Module EVO rather than the RS-232 V2 module.

Gage connectionModelsWireless (MobileCollect)Wired (GageWay)
54-115-333
Series 54, ULTRA, EURO
80
54-115-527
Series 54, ULTRA
49
54-115-444
Series 54
17
905338
Series 54
7
22806-MIT
Series 54
7
959149
Series 54
6
Ask MicroRidge
Series 54
6Ask MicroRidgeNot offered
RS-232, DB9 male
Series 54
6
RS-232, DB9 female, null modem3

Prices are U.S. list. The builder adds the base receiver or GageWay interface for your computer and checks each model.

Check the part number for output

Fowler sells many gages with and without output, and in the current Ultra-Cal VI line the part number tells you which port a caliper has: some numbers have Bluetooth built in, others use the proximity cable, and others have no output. The builder lists each model, and models without output are at the bottom of this page.

MobileCollect or Bluetooth

Many current Fowler Sylvac gages have Bluetooth built in and pair with Fowler’s USB Bluetooth receiver. MobileCollect is the choice when a floor mixes Fowler gages with other brands, when gages sit behind metal or among machines, or when more gages need to report to one computer. The RM2.4 versus Bluetooth white paper compares range and battery life, including the Fowler/Sylvac S_Cal EVO.

For fixed stations, RS-232 Fowler gages connect to an RS-232 Remote or a GageWay Pro channel through the GW-LC level converter.

Fowler series in the builder

Calipers 78

SeriesGage typesModelsConnection
54Ultra-Cal VI, Internal Electronic Caliper, External Electronic Caliper7254-115-333, 54-115-527, 22806-MIT; 30 without data output
OtherCaliper254-115-333
ULTRACaliper254-115-333, 54-115-527
EUROCaliper154-115-333
PROCaliper154-115-333

Indicators 55

SeriesGage typesModelsConnection
54Mark VI Indicator, Mark IV Indicator, S_Dial One Indicators4854-115-527, 54-115-333, 54-115-444; 4 without data output
OtherIndicator554-115-333, 54-115-444
ULTRAIndicator254-115-333

Micrometers 35

SeriesGage typesModelsConnection
54Micrometer, IP54 Micrometer - USB output, IP54 Blade Micrometer3354-115-527, 54-115-333, 905338; 17 without data output
OtherMicrometer254-115-333, 54-115-527

Height gages 30

SeriesGage typesModelsConnection
54Mini-Vertical Series II, Digital Ultra-Height Gages, Vertical Scale1654-115-333, RS-232, DB9 male, 54-115-527; 2 without data output
OtherHeight Gage1454-115-333, RS-232, DB9 male, RS-232, DB9 female, null modem; 1 without data output

Other gages 19

SeriesGage typesModelsConnection
54Ultra-Light Mark III, Gage output not supported, MicroGage1754-115-333, 54-115-527; 7 without data output
OtherGage output not supported, Discontinued item21 without data output

Depth gages 10

SeriesGage typesModelsConnection
54Depth Gage, Sylvac Euro-Depth Gage, Sylvac Depth Gage954-115-333; 3 without data output
OtherDepth Gage154-115-333

Bore gages 10

SeriesGage typesModelsConnection
OtherHolemike, Digital Holemike - OPTO, Digital Holemike - PROX1054-115-527, 54-115-444, 54-115-333

Scales and balances 9

SeriesGage typesModelsConnection
54Scale, Horizontal Scale954-115-333

Thickness gages 2

SeriesGage typesModelsConnection
54Digital Thickness Gage, Xtra-Value Digital Thickness Gage22 without data output

Questions

Will a simplex opto cable work on a duplex gage?

Yes. A simplex cable reads a duplex gage, but the gage ignores commands from the computer. Use the duplex cable when your software needs to request readings or change gage settings.


Do Fowler gages work on the same system as my Mitutoyo gages?

Yes. One MobileCollect base takes readings from every transmitter, and a GageWay Pro reads Digimatic and RS-232 gages side by side. Only the connector on each gage changes.


How do I find the right connector for my Fowler gage?

Search the model number in the System Builder. It lists the connector, transmitter and base, or tells you the model has no output.

Every Fowler model in the builder

Select a model to open it in the System Builder with the transmitter, cable and base.

Indicators

Other: Dialmatic, Mini Resist, QuadraTest, Series 213, Ultra Digit Mini

54 series: 54-520-305-0, 54-520-310-0, 54-520-320-0, 54-520-555, 54-520-600, 54-520-605, 54-520-610, 54-520-680-1, 54-520-680-2, 54-520-680-3, 54-520-777, 54-520-790, 54-520-791, 54-520-792, 54-520-794, 54-520-875, 54-520-876, 54-520-888, 54-520-900, 54-520-905, 54-530-124, 54-530-125, 54-530-134, 54-530-135, 54-530-136, 54-530-137, 54-530-144, 54-530-145, 54-530-154, 54-530-155, 54-530-156, 54-530-157, 54-530-164, 54-530-174, 54-530-175, 54-530-195, 54-530-215, 54-530-335, 54-530-355, 54-530-535, 54-530-555, 54-530-630, 54-562-777, 54-562-888

ULTRA series: Ultra-Digit Mark IV, Ultra-Digit Mark V

Calipers

Other: S_Cal, Ultra Cal III

54 series: 54-100-000-2, 54-100-004-2, 54-100-008-2, 54-100-012-0, 54-100-020-0, 54-100-040-0, 54-100-067-1, 54-100-067-C, 54-100-068-1, 54-100-069-1, 54-100-080-0, 54-100-112-2, 54-100-212, 54-100-330, 54-100-340, 54-100-400, 54-100-412-0, 54-100-412-1, 54-100-444-0, 54-100-444-1, 54-100-448-0, 54-100-448-1, 54-100-712-2, 54-100-777-2, 54-110-512, 54-110-540, 54-110-560, 54-110-580, 54-110-600, 54-110-650, 54-112-100-0, 54-112-300-0, 54-112-600-0, 54-200-777, 54-200-888, 54-554-005-2, 54-554-010-2, 54-554-012-2, 54-554-013-2, 54-554-030-2, 54-554-050-2, 54-554-070-2

EURO series: Euro-Cal III

PRO series: Pro-Max

ULTRA series: Ultra-Cal IV, Ultra-Cal V

Height gages

Other: Digital Ultra, Hi CAL, Mestra-Touch, MiniVertical Series II, Trimos Mestra, Trimos Mestra Touch, Trimos TVM, Trimos V+ Series, Trimos Vectra Plus, Trimos V Series, Vectra-Touch, Vertical 500A, Z_Cal 350 / 600

54 series: 54-050-025, 54-050-035, 54-105-012-0, 54-105-024-0, 54-105-040-0, 54-180-212-0, 54-180-215-0, 54-180-224-0, 54-180-226-0, 54-212-016-1, 54-212-024-1, 54-931-150-0, 54-931-300-0, 54-931-450-0

Micrometers

Other: S_Mike, S_Mike Pro

54 series: 54-245-777, 54-245-780, 54-245-800, 54-245-825, 54-815-030-0, 54-815-060-0, 54-815-100-0, 54-815-110-0, 54-815-111-0, 54-815-112-0, 54-815-130-0, 54-815-160-0, 54-880-001-0, 54-880-002-0, 54-880-003-0, 54-880-004-0

Other gages

Other: S_Dial One Indicator

54 series: 54-110-312, 54-110-324, 54-110-340, 54-110-360, 54-150-012-0, 54-551-001-0, 54-551-002-0, 54-551-003-0, 54-551-004-0, 54-866-XXX

Bore gages

Other: Mark II, XT (not xtreme), XT3 Series, XT500 Series, XTD3 Series, XTD Series, XTH3 Series, XTH Series, XTL Series, XT xtreme

Scales and balances

54 series: 54-050-004, 54-050-005, 54-050-013, 54-050-015, 54-998-108, 54-998-120, 54-998-124, 54-998-130, 54-998-140

Depth gages

Other: Depthmatic

54 series: 54-137-008, 54-137-012, 54-138-012, 54-138-020, 54-275-065, 54-275-100

Calipers without data output: 54-100-024-1, 54-100-042-1, 54-100-100-0, 54-100-167-0, 54-100-167-C, 54-100-168-0, 54-100-169-0, 54-100-177-0, 54-100-178-0, 54-100-179-0, 54-100-312-0, 54-101-150-2, 54-101-200-1, 54-101-300-1, 54-103-006-0, 54-103-012-0, 54-550-000, 54-550-300, 54-554-611, 54-554-622, 54-554-623, 54-554-624, 54-554-625, 54-554-630, 54-554-711, 54-554-722, 54-554-723, 54-554-724, 54-554-725, 54-554-730-0. These models have no data output, so no cable or transmitter can read them.

Height gages without data output: 54-106-020-0, 54-106-040-0, Z-Height-E. These models have no data output, so no cable or transmitter can read them.

Other gages without data output: 54-115-778, 54-115-779, 54-150-004-0, 54-150-020, 54-175-012, 54-175-024, 54-554-930, Quadramic. These models have no data output, so no cable or transmitter can read them.

Depth gages without data output: 54-125-777, 54-225-456-0, 54-225-xxx. These models have no data output, so no cable or transmitter can read them.

Indicators without data output: 54-520-025-1, 54-520-250-0, 54-520-255-0, 54-520-260-0. These models have no data output, so no cable or transmitter can read them.

Thickness gages without data output: 54-550-500, 54-554-830-0. These models have no data output, so no cable or transmitter can read them.

Micrometers without data output: 54-815-001, 54-816-025-0, 54-860-001-1, 54-860-002-1, 54-860-003-1, 54-860-004-1, 54-860-005-1, 54-860-006-1, 54-860-211-0, 54-860-241-0, 54-860-242-0, 54-860-243-0, 54-860-244-0, 54-870-001-0, 54-870-002-0, 54-870-003-0, 54-870-004-0. These models have no data output, so no cable or transmitter can read them.