Designed & Made in the USA Since 1983
Mahr and Mahr Federal Gage Data Collection

Mahr and Mahr Federal Gage Data Collection

Mahr gages, including the Federal Products line that became Mahr Federal and is now Mahr Inc., use several data connections. Current MarCal calipers and MarCator indicators have Mahr’s MarConnect output, older Federal gages have their own connectors, and Millimar and Digimar instruments use RS-232. This page shows which MicroRidge parts read each Mahr model in the System Builder.

489Mahr gage models in the builder
376with data output
23connection types

Find your Mahr gage in the builderOr describe your application to the System Advisor

Counts come from the MicroRidge Measurement Collection System Builder and update when the gage data does.

Mahr connections

  • MarConnect Digimatic (4102915). Mahr’s 16 EWd Digimatic cable, with a data button, fits MarCal calipers, depth gages, MarCator indicators and Micromar micrometers with the MarConnect socket. Its output is Mitutoyo Digimatic compatible, so it plugs straight into a GageWay interface or a Digital Remote. MicroRidge also offers the MobileCollect connector for it. The 4102606 is Mahr’s two-way version of the same cable.
  • MarConnect RS-232 (4102410). Mahr’s 16 EXr opto RS-232 cable for the same socket, for the RS-232 Remote or a GageWay Pro channel.
  • Extramess gages (4346021 and 4346020). Millimess and MarCator indicators with Mahr’s 4-pin Extramess connector take the 4346021 Digimatic cable or the 4346020 RS-232 cable. MicroRidge’s 434602N connector reads them wirelessly.
  • Federal Maxum and µMaxum. Maxum gages have a 6-pin or 10-pin output, depending on the model, µMaxum and µMaxum XL gages a 7-pin output, and µMaxum II gages the 4-pin Extramess connector. MicroRidge makes a cable for each.
  • Millimar, Digimar and other instruments. These have a 9-pin serial port and connect like any RS-232 instrument.
Gage connectionModelsWireless (MobileCollect)Wired (GageWay)
4102915148
Ask MicroRidge50Ask MicroRidgeNot offered
434602N43
FED-MAX36
  • Mini Mobile Module EVO + MC-M3-FED-MAX-X (quoted by MicroRidge)
  • Command Mobile Module + MC-D-FED-MAX-X (quoted by MicroRidge)
  • Digital Remote + Mahr Federal Maxum Gage Cable $175
RS-232, DB9 female, null modem19
22806-MIT15
54-115-33314
FED-MAX-E212
  • Mini Mobile Module EVO + MC-M3-FED-MAX-E2-X (quoted by MicroRidge)
  • Command Mobile Module + MC-D-FED-MAX-E2-X (quoted by MicroRidge)
  • Digital Remote + Mahr Federal Maxum E-2 Gage Cable $175
FED-MICRO
Series EDI, XLI, XLT
8
54-115-4445
RS-232, 41024105Ask MicroRidgeNot offered
RS-232, Mahr3Ask MicroRidgeNot offered

11 more connections are used by 18 other models: RS-232, Mahr data output, 4102915-PS10, 434602N-PSIV, RS-232, OPTO, RS-232, DB9 male, RS-232, Mahr Opto, RS-232, Mahr 4102915, RS-232, Mahr 4-pin, RS-232, Mahr 6-pin or 10-pin ro female, FED-MAX-E3, RS-232, Varies with model. The builder has the parts for each.

Prices are U.S. list. The builder adds the base receiver or GageWay interface for your computer and checks each model.

Models that need a sales check

A few Mahr gages need the original RM2.4 transmitter rather than the Mini Mobile Module EVO, including the Pocket Surf IV, PS1 and 10 surface testers and Federal Maxum gages. The builder marks these models, and MicroRidge sales confirms the right transmitter before you order.

MobileCollect or Mahr Integrated Wireless

Mahr’s own Integrated Wireless models (the “i” models, such as the MarCal 16 EWRi) send to an i-Stick USB receiver up to about 6 m away, with up to eight gages per stick. MobileCollect works with Mahr’s cabled models, reaches about 140 feet, and puts Mahr gages on the same base as Mitutoyo, Starrett, Fowler and RS-232 instruments. The wireless white paper compares the two.

For fixed stations, Mahr’s Digimatic cables plug straight into a GageWay, and a GageWay Pro reads Mahr and RS-232 instruments side by side. Our check fixture guide covers multi-gage stations.

Mahr series in the builder

Indicators 124

SeriesGage typesModelsConnection
OtherIndicator, Millimess Maxum III comparator ±1mm, Millimess Maxum III comparator ±1.99mm1244102915, 434602N, FED-MAX; 12 without data output

Calipers 118

SeriesGage typesModelsConnection
OtherMarameter 838 EI inside caliper gage, MarCal 16 ER caliper 0-150mm/0-6in, MarCal 16 EWR caliper 0-150mm/0-6in1184102915, 22806-MIT, RS-232, Mahr Opto; 51 without data output

Micrometers 66

SeriesGage typesModelsConnection
Other40 EWRi micrometer, 40 EWRi-L micrometer, 40 EWRi-V micrometer664102915; 33 without data output

Other gages 49

SeriesGage typesModelsConnection
OtherAir Gage, MarCal Machine Gage, Protractor48FED-MAX, 434602N, FED-MICRO; 1 without data output
XLTGage1FED-MICRO

Depth gages 30

SeriesGage typesModelsConnection
OtherMarCal 30 EWRi depth gage, 30 EWRi-D depth gage, Depth Gage304102915, 54-115-333; 14 without data output

Height gages 24

SeriesGage typesModelsConnection
OtherHeight Gage, Digimar 814 SR height gage 0-350mm, Digimar 814 SR height gage 0-600mm2454-115-333, 4102915, RS-232, OPTO

Bore gages 24

SeriesGage typesModelsConnection
OtherMicromar 44 EWR inside micrometer, Micromar 44 EWg inside micrometer unit, Micromar 44 EWR inside micrometer 6-8mm244102915

Displays and counters 22

SeriesGage typesModelsConnection
OtherCompact amplifier, Millimess Maxum III display, Millimar S 1840 F column amplifier22RS-232, DB9 female, null modem, 434602N, FED-MAX; 1 without data output

Hardness and surface testers 21

SeriesGage typesModelsConnection
OtherMarSurf PS 10 roughness tester, Roughness Tester, Surface Gage214102915-PS10, 434602N-PSIV, RS-232, DB9 male

Thickness gages 9

SeriesGage typesModelsConnection
OtherMarameter EMD-57B-11 thickness gage, Marameter EMD-57B-11D thickness gage *, Marameter XLI-22P-20 thickness gage74102915, FED-MAX; 1 without data output
EDIThickness Gage1FED-MICRO
XLIThickness Gage1FED-MICRO

Scales and balances 2

SeriesGage typesModelsConnection
OtherLinear Machine Scale254-115-333

Questions

Can I use the Mahr Digimatic cable I already have?

Yes, on a wired system. Mahr’s 4102915 and 4346021 cables end in a Digimatic plug that fits a GageWay interface or a Digital Remote directly. For wireless collection, MicroRidge’s MobileCollect connector replaces the cable.


Do Mahr gages work with my SPC software?

Yes. MobileCollect bases and GageWay interfaces deliver readings as keyboard input or through a COM port, which SPC software and Excel accept. See our SPC software partners.


How do I find the right cable for my Mahr gage?

Search the model number in the System Builder. It lists the cable or connector for that model, flags gages that need a sales check, and tells you if a model has no output.

Every Mahr model in the builder

Select a model to open it in the System Builder with the transmitter, cable and base.

Indicators

Other: 800EW, 800EWR, 1086R, 1087 BRi, 1087 R, 1087 Ri, 1087 Ri HR, 1087 ZR, 2000, 2001, 2100, 2033111, 2033112, 2033113, 2033114, 2033115, 2033116, 2033117, 2033118, 2033121, 2033122, 2033123, 2033124, 2033125, 2033126, 2033127, 2033128, 2034101, 2034103, 2034105, 2034107, 2034201, 2034203, 2034205, 2034207, 2051693, 2051694, 2051695, 2051696, 2051864, 2051871, 2051874, 2051881, 2061657, 2061658, 4305120, 4306120, 4336010, 4336020, 4336030, 4337130, 4337131, 4337132, 4337133, 4337134, 4337135, 4337142, 4337143, 4337620, 4337621, 4337622, 4337623, 4337624, 4337625, 4337626, 4337627, 4337628, 4337640, 4337641, 4337650, 4337651, 4337660, 4337661, 4337662, 4337663, 4337664, 4337665, 4337666, 4337667, 4337670, 4337671, 4337695, 4337696, 4337697, 4337698, 4346700, 4346701, 4346800, 4346801, 4346811, DEI models - all, Extramess 2000 (4 pin) *, Extramess 2001 (4 pin) *, MarCator 1075, MarCator 1080, MarCator 1081, MarCator 1082, MarCator 1086, MarCator 1087, MarCator 1088 (4 pin), Maxum (6 pin) *, Maxum E2 (10 pin), Maxum III, Maxum III (6 pin) *, Maxum III (10 pin), Maxum Plus DEI-XX1XX (10 pin), Millimess 2100 (4 pin) *, Millitast 1083 (OPTO), Millitast 1085 (OPTO), uMaxum (7 pin), uMaxum II XL (4 pin), uMaxum XL (7 pin)

Calipers

Other: 16 ES, 16 EW, 16 EWR, 16 EX, 25 ES (OPTO), 4103014, 4103015, 4103016, 4103017, 4103018, 4103019, 4103020, 4103021, 4103064, 4103065, 4103066, 4103067, 4103068, 4103069, 4103070, 4103071, 4103072, 4103073, 4103074, 4103075, 4103076, 4103077, 4103078, 4103079, 4103080, 4103081, 4103082, 4103083, 4103084, 4103085, 4112704, 4112705, 4112712, 4112713, 4112714, 4112715, 4112716, 4112717, 4112722, 4112723, 4118807, 4118808, 4119000, 4119001, 4119002, 4119003, 4495450, 4495451, 4495452, 4495453, 4495454, 4495455, 4495456, 4495460, 4495461, 4495462, 4495463, 4495464, 4495465, 4495468, 4495469, 4495470

Other gages

Other: 31 EW (POWER), 106 ES (OPTO), 300 P (7 pin), 832, 2033119, 2051658, 2051664, 2051666, 2051668, 2051669, 2051670, 2051671, 2051672, 2051673, 2051674, 2051680, 2051681, 2051687, 2051688, 2051689, 2051690, 2051691, 2051692, 2051730, 2051734, 2051758, 2051762, 2051766, 2051770, 2051774, 2051778, 2051782, 2051806, 2051810, 2051834, 2051838, 2051842, 2051846, 2051850, 2051854, 2051858, 2103200, Dimensionair 832 (DB9 male), Dimensionair 2095389 (7 pin), Dimensionair EAG-3XXX (6 pin), SM 60, uDimensionair (7 pin)

XLT series: XLT-X000X (7 pin)

Micrometers

Other: 40 EW, 40 EWR (2017 and earlier), 40 EWS, 40 EWW, 46 EX, 4157000, 4157001, 4157002, 4157003, 4157004, 4157005, 4157006, 4157007, 4157015, 4157020, 4157021, 4157022, 4157023, 4157030, 4157031, 4157032, 4157033, 4157040, 4157041, 4157042, 4157043, 4157044, 4157045, 4157046, 4157047, 4157048, 4157050, 4157400

Height gages

Other: 27 ES (OPTO), 30 EXN, 4426100, 4426100 / 4426101, 4426101, 4426540, 4426540 / 4426542, 4426541, 4426541 / 4426543, 4426542, 4426543, 4429010 / 4429011 / 4429012, 4429030, 4429030 / 4429031, 4429031, 4429600, 4429601, 4429602, 4429630, 4429631, Digimar 814 S, Digimar 814 X (OPTO), Digimar 817 CLM (DB9 male), M814 (OPTO)

Bore gages

Other: 4190106, 4190107, 4190108, 4191032, 4191033, 4191034, 4191035, 4191036, 4191037, 4191120, 4191121, 4191122, 4191123, 4191124, 4191125, 4191126, 4191127, 4191129, 4191130, 4191131, 4191160, 4191161, 4191162, 4191163

Displays and counters

Other: 2033011, 2033021, 5312011, 5312012, 5312025, 5318400, 5318402, 5318455, 5318457, C1200, C1202, C1208, C1216, C1240, C1245, Millimar C1208, Millimar C1216, Millimar C1240, Millimar C1245, S 1840, S 1840 PE

Hardness and surface testers

Other: 2191800, 2191802, 6910230 HW Ver 1, 6910230 HW Ver 2, 6910232 HW Ver 1, 6910232 HW Ver 2, 6910260, 6910264, 6910265, 6910267, 6910268, 6910295, M300 (DB9 female), M300C (DB9 female), Perthometer M1, Pocket Surf III (3 pin), Pocket Surf PS1 (D/T/Value), Pocket Surf PS1 (Value only), PS10, PS I, PS IV

Depth gages

Other: 30 ER, 30 EWD (OPTO), 30 EWN, 4126513, 4126523, 4126524, 4126525, 4126526, 4126651, 4126652, 4126653, 4126654, 4126699, 4126700, 4126701, 4126702

Thickness gages

Other: 2051885, 2057541, 2057548, 2057549, 2057550, 2057551

EDI series: EDI-578-XX (7 pin) *

XLI series: XLI-22P-20 (7 pin)

Scales and balances

Other: 31 ES (OPTO), 32 ES (OPTO)

Calipers without data output: 16 N, 4103010, 4103011, 4103012, 4103013, 4103205, 4103206, 4103207, 4103208, 4103300, 4103301, 4103302, 4103303, 4103304, 4103305, 4103306, 4103307, 4103372, 4103373, 4103374, 4103375, 4103376, 4103377, 4103378, 4103379, 4103380, 4103381, 4103382, 4103383, 4103384, 4103385, 4103400, 4103401, 4103402, 4103403, 4103404, 4103405, 4103406, 4103407, 4112571, 4112572, 4112573, 4112574, 4112621, 4112622, 4112623, 4118907, 4119050, 4119051, 4119052, 4119053. These models have no data output, so no cable or transmitter can read them.

Displays and counters without data output: 2033001. These models have no data output, so no cable or transmitter can read them.

Indicators without data output: 2033101, 2033102, 2033103, 2033104, 2033105, 2033106, 2033107, 2033108, 2050665, 2050666, 2051863, 2051873. These models have no data output, so no cable or transmitter can read them.

Thickness gages without data output: 2051884. These models have no data output, so no cable or transmitter can read them.

Depth gages without data output: 4126532, 4126533, 4126534, 4126535, 4126536, 4126671, 4126672, 4126673, 4126674, 4126751, 4126754, 4126755, 4126756, 4126757. These models have no data output, so no cable or transmitter can read them.

Micrometers without data output: 4157010, 4157011, 4157012, 4157013, 4157014, 4157100, 4157101, 4157102, 4157103, 4157104, 4157105, 4157106, 4157107, 4157115, 4157120, 4157121, 4157122, 4157123, 4157130, 4157131, 4157132, 4157133, 4157140, 4157141, 4157142, 4157143, 4157144, 4157145, 4157146, 4157147, 4157148, 4157150, 4157410. These models have no data output, so no cable or transmitter can read them.

Other gages without data output: 4304300. These models have no data output, so no cable or transmitter can read them.