Mahr gages, including the Federal Products line that became Mahr Federal and is now Mahr Inc., use several data connections. Current MarCal calipers and MarCator indicators have Mahr’s MarConnect output, older Federal gages have their own connectors, and Millimar and Digimar instruments use RS-232. This page shows which MicroRidge parts read each Mahr model in the System Builder.
Find your Mahr gage in the builderOr describe your application to the System Advisor
Counts come from the MicroRidge Measurement Collection System Builder and update when the gage data does.
Mahr connections
- MarConnect Digimatic (4102915). Mahr’s 16 EWd Digimatic cable, with a data button, fits MarCal calipers, depth gages, MarCator indicators and Micromar micrometers with the MarConnect socket. Its output is Mitutoyo Digimatic compatible, so it plugs straight into a GageWay interface or a Digital Remote. MicroRidge also offers the MobileCollect connector for it. The 4102606 is Mahr’s two-way version of the same cable.
- MarConnect RS-232 (4102410). Mahr’s 16 EXr opto RS-232 cable for the same socket, for the RS-232 Remote or a GageWay Pro channel.
- Extramess gages (4346021 and 4346020). Millimess and MarCator indicators with Mahr’s 4-pin Extramess connector take the 4346021 Digimatic cable or the 4346020 RS-232 cable. MicroRidge’s 434602N connector reads them wirelessly.
- Federal Maxum and µMaxum. Maxum gages have a 6-pin or 10-pin output, depending on the model, µMaxum and µMaxum XL gages a 7-pin output, and µMaxum II gages the 4-pin Extramess connector. MicroRidge makes a cable for each.
- Millimar, Digimar and other instruments. These have a 9-pin serial port and connect like any RS-232 instrument.
| Gage connection | Models | Wireless (MobileCollect) | Wired (GageWay) |
|---|---|---|---|
| 4102915 | 148 |
|
|
| Ask MicroRidge | 50 | Ask MicroRidge | Not offered |
| 434602N | 43 |
|
|
| FED-MAX | 36 |
| |
| RS-232, DB9 female, null modem | 19 |
|
|
| 22806-MIT | 15 |
|
|
| 54-115-333 | 14 |
| |
| FED-MAX-E2 | 12 |
| |
| FED-MICRO Series EDI, XLI, XLT | 8 |
| |
| 54-115-444 | 5 |
| |
| RS-232, 4102410 | 5 | Ask MicroRidge | Not offered |
| RS-232, Mahr | 3 | Ask MicroRidge | Not offered |
11 more connections are used by 18 other models: RS-232, Mahr data output, 4102915-PS10, 434602N-PSIV, RS-232, OPTO, RS-232, DB9 male, RS-232, Mahr Opto, RS-232, Mahr 4102915, RS-232, Mahr 4-pin, RS-232, Mahr 6-pin or 10-pin ro female, FED-MAX-E3, RS-232, Varies with model. The builder has the parts for each.
Prices are U.S. list. The builder adds the base receiver or GageWay interface for your computer and checks each model.
Models that need a sales check
A few Mahr gages need the original RM2.4 transmitter rather than the Mini Mobile Module EVO, including the Pocket Surf IV, PS1 and 10 surface testers and Federal Maxum gages. The builder marks these models, and MicroRidge sales confirms the right transmitter before you order.
MobileCollect or Mahr Integrated Wireless
Mahr’s own Integrated Wireless models (the “i” models, such as the MarCal 16 EWRi) send to an i-Stick USB receiver up to about 6 m away, with up to eight gages per stick. MobileCollect works with Mahr’s cabled models, reaches about 140 feet, and puts Mahr gages on the same base as Mitutoyo, Starrett, Fowler and RS-232 instruments. The wireless white paper compares the two.
For fixed stations, Mahr’s Digimatic cables plug straight into a GageWay, and a GageWay Pro reads Mahr and RS-232 instruments side by side. Our check fixture guide covers multi-gage stations.
Mahr series in the builder
Indicators 124
| Series | Gage types | Models | Connection |
|---|---|---|---|
| Other | Indicator, Millimess Maxum III comparator ±1mm, Millimess Maxum III comparator ±1.99mm | 124 | 4102915, 434602N, FED-MAX; 12 without data output |
Calipers 118
| Series | Gage types | Models | Connection |
|---|---|---|---|
| Other | Marameter 838 EI inside caliper gage, MarCal 16 ER caliper 0-150mm/0-6in, MarCal 16 EWR caliper 0-150mm/0-6in | 118 | 4102915, 22806-MIT, RS-232, Mahr Opto; 51 without data output |
Micrometers 66
| Series | Gage types | Models | Connection |
|---|---|---|---|
| Other | 40 EWRi micrometer, 40 EWRi-L micrometer, 40 EWRi-V micrometer | 66 | 4102915; 33 without data output |
Other gages 49
| Series | Gage types | Models | Connection |
|---|---|---|---|
| Other | Air Gage, MarCal Machine Gage, Protractor | 48 | FED-MAX, 434602N, FED-MICRO; 1 without data output |
| XLT | Gage | 1 | FED-MICRO |
Depth gages 30
| Series | Gage types | Models | Connection |
|---|---|---|---|
| Other | MarCal 30 EWRi depth gage, 30 EWRi-D depth gage, Depth Gage | 30 | 4102915, 54-115-333; 14 without data output |
Height gages 24
| Series | Gage types | Models | Connection |
|---|---|---|---|
| Other | Height Gage, Digimar 814 SR height gage 0-350mm, Digimar 814 SR height gage 0-600mm | 24 | 54-115-333, 4102915, RS-232, OPTO |
Bore gages 24
| Series | Gage types | Models | Connection |
|---|---|---|---|
| Other | Micromar 44 EWR inside micrometer, Micromar 44 EWg inside micrometer unit, Micromar 44 EWR inside micrometer 6-8mm | 24 | 4102915 |
Displays and counters 22
| Series | Gage types | Models | Connection |
|---|---|---|---|
| Other | Compact amplifier, Millimess Maxum III display, Millimar S 1840 F column amplifier | 22 | RS-232, DB9 female, null modem, 434602N, FED-MAX; 1 without data output |
Hardness and surface testers 21
| Series | Gage types | Models | Connection |
|---|---|---|---|
| Other | MarSurf PS 10 roughness tester, Roughness Tester, Surface Gage | 21 | 4102915-PS10, 434602N-PSIV, RS-232, DB9 male |
Thickness gages 9
| Series | Gage types | Models | Connection |
|---|---|---|---|
| Other | Marameter EMD-57B-11 thickness gage, Marameter EMD-57B-11D thickness gage *, Marameter XLI-22P-20 thickness gage | 7 | 4102915, FED-MAX; 1 without data output |
| EDI | Thickness Gage | 1 | FED-MICRO |
| XLI | Thickness Gage | 1 | FED-MICRO |
Scales and balances 2
| Series | Gage types | Models | Connection |
|---|---|---|---|
| Other | Linear Machine Scale | 2 | 54-115-333 |
Questions
Yes, on a wired system. Mahr’s 4102915 and 4346021 cables end in a Digimatic plug that fits a GageWay interface or a Digital Remote directly. For wireless collection, MicroRidge’s MobileCollect connector replaces the cable. Yes. MobileCollect bases and GageWay interfaces deliver readings as keyboard input or through a COM port, which SPC software and Excel accept. See our SPC software partners. Search the model number in the System Builder. It lists the cable or connector for that model, flags gages that need a sales check, and tells you if a model has no output.Can I use the Mahr Digimatic cable I already have?
Do Mahr gages work with my SPC software?
How do I find the right cable for my Mahr gage?
Every Mahr model in the builder
Select a model to open it in the System Builder with the transmitter, cable and base.
Indicators
Other: 800EW, 800EWR, 1086R, 1087 BRi, 1087 R, 1087 Ri, 1087 Ri HR, 1087 ZR, 2000, 2001, 2100, 2033111, 2033112, 2033113, 2033114, 2033115, 2033116, 2033117, 2033118, 2033121, 2033122, 2033123, 2033124, 2033125, 2033126, 2033127, 2033128, 2034101, 2034103, 2034105, 2034107, 2034201, 2034203, 2034205, 2034207, 2051693, 2051694, 2051695, 2051696, 2051864, 2051871, 2051874, 2051881, 2061657, 2061658, 4305120, 4306120, 4336010, 4336020, 4336030, 4337130, 4337131, 4337132, 4337133, 4337134, 4337135, 4337142, 4337143, 4337620, 4337621, 4337622, 4337623, 4337624, 4337625, 4337626, 4337627, 4337628, 4337640, 4337641, 4337650, 4337651, 4337660, 4337661, 4337662, 4337663, 4337664, 4337665, 4337666, 4337667, 4337670, 4337671, 4337695, 4337696, 4337697, 4337698, 4346700, 4346701, 4346800, 4346801, 4346811, DEI models - all, Extramess 2000 (4 pin) *, Extramess 2001 (4 pin) *, MarCator 1075, MarCator 1080, MarCator 1081, MarCator 1082, MarCator 1086, MarCator 1087, MarCator 1088 (4 pin), Maxum (6 pin) *, Maxum E2 (10 pin), Maxum III, Maxum III (6 pin) *, Maxum III (10 pin), Maxum Plus DEI-XX1XX (10 pin), Millimess 2100 (4 pin) *, Millitast 1083 (OPTO), Millitast 1085 (OPTO), uMaxum (7 pin), uMaxum II XL (4 pin), uMaxum XL (7 pin)
Calipers
Other: 16 ES, 16 EW, 16 EWR, 16 EX, 25 ES (OPTO), 4103014, 4103015, 4103016, 4103017, 4103018, 4103019, 4103020, 4103021, 4103064, 4103065, 4103066, 4103067, 4103068, 4103069, 4103070, 4103071, 4103072, 4103073, 4103074, 4103075, 4103076, 4103077, 4103078, 4103079, 4103080, 4103081, 4103082, 4103083, 4103084, 4103085, 4112704, 4112705, 4112712, 4112713, 4112714, 4112715, 4112716, 4112717, 4112722, 4112723, 4118807, 4118808, 4119000, 4119001, 4119002, 4119003, 4495450, 4495451, 4495452, 4495453, 4495454, 4495455, 4495456, 4495460, 4495461, 4495462, 4495463, 4495464, 4495465, 4495468, 4495469, 4495470
Other gages
Other: 31 EW (POWER), 106 ES (OPTO), 300 P (7 pin), 832, 2033119, 2051658, 2051664, 2051666, 2051668, 2051669, 2051670, 2051671, 2051672, 2051673, 2051674, 2051680, 2051681, 2051687, 2051688, 2051689, 2051690, 2051691, 2051692, 2051730, 2051734, 2051758, 2051762, 2051766, 2051770, 2051774, 2051778, 2051782, 2051806, 2051810, 2051834, 2051838, 2051842, 2051846, 2051850, 2051854, 2051858, 2103200, Dimensionair 832 (DB9 male), Dimensionair 2095389 (7 pin), Dimensionair EAG-3XXX (6 pin), SM 60, uDimensionair (7 pin)
XLT series: XLT-X000X (7 pin)
Micrometers
Other: 40 EW, 40 EWR (2017 and earlier), 40 EWS, 40 EWW, 46 EX, 4157000, 4157001, 4157002, 4157003, 4157004, 4157005, 4157006, 4157007, 4157015, 4157020, 4157021, 4157022, 4157023, 4157030, 4157031, 4157032, 4157033, 4157040, 4157041, 4157042, 4157043, 4157044, 4157045, 4157046, 4157047, 4157048, 4157050, 4157400
Height gages
Other: 27 ES (OPTO), 30 EXN, 4426100, 4426100 / 4426101, 4426101, 4426540, 4426540 / 4426542, 4426541, 4426541 / 4426543, 4426542, 4426543, 4429010 / 4429011 / 4429012, 4429030, 4429030 / 4429031, 4429031, 4429600, 4429601, 4429602, 4429630, 4429631, Digimar 814 S, Digimar 814 X (OPTO), Digimar 817 CLM (DB9 male), M814 (OPTO)
Bore gages
Other: 4190106, 4190107, 4190108, 4191032, 4191033, 4191034, 4191035, 4191036, 4191037, 4191120, 4191121, 4191122, 4191123, 4191124, 4191125, 4191126, 4191127, 4191129, 4191130, 4191131, 4191160, 4191161, 4191162, 4191163
Displays and counters
Other: 2033011, 2033021, 5312011, 5312012, 5312025, 5318400, 5318402, 5318455, 5318457, C1200, C1202, C1208, C1216, C1240, C1245, Millimar C1208, Millimar C1216, Millimar C1240, Millimar C1245, S 1840, S 1840 PE
Hardness and surface testers
Other: 2191800, 2191802, 6910230 HW Ver 1, 6910230 HW Ver 2, 6910232 HW Ver 1, 6910232 HW Ver 2, 6910260, 6910264, 6910265, 6910267, 6910268, 6910295, M300 (DB9 female), M300C (DB9 female), Perthometer M1, Pocket Surf III (3 pin), Pocket Surf PS1 (D/T/Value), Pocket Surf PS1 (Value only), PS10, PS I, PS IV
Depth gages
Other: 30 ER, 30 EWD (OPTO), 30 EWN, 4126513, 4126523, 4126524, 4126525, 4126526, 4126651, 4126652, 4126653, 4126654, 4126699, 4126700, 4126701, 4126702
Thickness gages
Other: 2051885, 2057541, 2057548, 2057549, 2057550, 2057551
EDI series: EDI-578-XX (7 pin) *
XLI series: XLI-22P-20 (7 pin)
Scales and balances
Other: 31 ES (OPTO), 32 ES (OPTO)
Calipers without data output: 16 N, 4103010, 4103011, 4103012, 4103013, 4103205, 4103206, 4103207, 4103208, 4103300, 4103301, 4103302, 4103303, 4103304, 4103305, 4103306, 4103307, 4103372, 4103373, 4103374, 4103375, 4103376, 4103377, 4103378, 4103379, 4103380, 4103381, 4103382, 4103383, 4103384, 4103385, 4103400, 4103401, 4103402, 4103403, 4103404, 4103405, 4103406, 4103407, 4112571, 4112572, 4112573, 4112574, 4112621, 4112622, 4112623, 4118907, 4119050, 4119051, 4119052, 4119053. These models have no data output, so no cable or transmitter can read them.
Displays and counters without data output: 2033001. These models have no data output, so no cable or transmitter can read them.
Indicators without data output: 2033101, 2033102, 2033103, 2033104, 2033105, 2033106, 2033107, 2033108, 2050665, 2050666, 2051863, 2051873. These models have no data output, so no cable or transmitter can read them.
Thickness gages without data output: 2051884. These models have no data output, so no cable or transmitter can read them.
Depth gages without data output: 4126532, 4126533, 4126534, 4126535, 4126536, 4126671, 4126672, 4126673, 4126674, 4126751, 4126754, 4126755, 4126756, 4126757. These models have no data output, so no cable or transmitter can read them.
Micrometers without data output: 4157010, 4157011, 4157012, 4157013, 4157014, 4157100, 4157101, 4157102, 4157103, 4157104, 4157105, 4157106, 4157107, 4157115, 4157120, 4157121, 4157122, 4157123, 4157130, 4157131, 4157132, 4157133, 4157140, 4157141, 4157142, 4157143, 4157144, 4157145, 4157146, 4157147, 4157148, 4157150, 4157410. These models have no data output, so no cable or transmitter can read them.
Other gages without data output: 4304300. These models have no data output, so no cable or transmitter can read them.